| TABLE III. Group A inspection for device type 06.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
MIL-
Cases E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Subgroup
Symbol
STD-883
Meas.
VCC
terminal
Min
Max
Unit
method
Test No.
CLR
J
A
B
C
D
GND
SL
CLK
QC
QB
QA
QD
QD
K
3006
1
2.0 V
2.0 V
2.0 V
2.0 V
2.0 V
GND
0.8 V
A 1/
2.4
V
1
-0.8 mA 4.5 V
VOH
QA
"
"
2
"
"
"
"
"
"
"
"
-0.8 mA
"
"
"
TC = 25C
QB
"
"
"
"
"
3
"
"
"
"
"
"
"
"
-0.8 mA
"
QC
"
"
"
"
"
4
"
"
"
"
"
"
"
"
-0.8 mA
"
QD
"
"
"
"
"
5
"
0.8 V
0.8 V
0.8 V
0.8 V
"
"
"
-0.8 mA
"
QD
3007
6
"
"
"
"
"
"
"
"
16 mA
"
0.4
"
"
QA
VOL
"
"
"
"
"
7
"
"
"
"
"
"
"
"
16 mA
"
QB
"
"
'`
"
"
8
"
"
"
"
"
"
"
"
16 mA
"
QC
"
"
"
"
9
"
"
"
"
"
"
"
"
16 mA
"
QD
"
"
"
"
"
"
10
"
2.0 V
2.0 V
2.0 V
2.0 V
"
"
"
16 mA
"
QD
"
11
-12 mA
"
"
CLR
-1.5
"
VIC
"
"
12
-12 mA
"
"
J
"
"
"
"
13
-12 mA
"
"
"
"
K
"
"
14
-12 mA
"
"
A
"
"
"
"
15
-12 mA
"
"
B
"
"
"
"
16
-12 mA
"
"
C
"
"
"
"
17
-12 mA
"
"
D
"
"
"
"
18
"
-12 mA
"
SL
"
"
"
"
19
"
-12 mA
"
CLK
"
"
3009
20
0.4 V
"
5.5 V
5.5 V
CLR
-0.4
-1.3
mA
"
IIL1
"
21
GND
0.4 V
"
5.5 V
"
J
"
IIL2
"
"
"
22
B 2/
5.5 V
0.4 V
5.5 V
"
5.5 V
A
"
7/
K
"
"
"
23
0.4 V
"
GND
"
A
"
"
"
24
0.4 V
"
"
"
B
"
"
"
25
0.4 V
"
"
"
C
"
"
"
26
0.4 V
"
"
"
D
"
"
"
27
"
0.4 V
"
SL
"
28
5.5 V
"
0.4 V
"
CLK
-0.7
-1.6
mA
"
IIL3
See footnotes at end of device type 06.
|