| MIL-M-60170A(MU)
Gage - Interchangeability - Body
F11738174
Maximum
Gage - Interchangeability - Body
F11738175
Minimum
Gage - Interchangeability - Head
F11738176
Minimum
Gage - Interchangeability - Head
F11738177
Maximum
Fixture - Pressure Testing - Head
F11738180
Maximum
Fixture - Pressure Testing - Head
F11738181
Minimum
Fixture - Pressure Testing - Body
F11738182
Maximum
Fixture - Pressure Testing - Body
F11738183
Minimum
PACKAGING DATA SHEET
10513360
Packaging of Mount, Periscope:
10513360
(Copies of specifications, standards, drawings and packaging data sheets
required by suppliers in connection with specific procurement functions
should be obtained from the procuring activity or as directed by the
contracting officer.)
3. REQUIREMENTS
3.1 Fabrication.- The periscope mount, hereinafter referred to as
"mount" shall be manufactured in accordance with Drawing F1051336O and
drawings pertaining thereto.
3.2 General specification.- The contractor shall be responsible
for adherence to, and compliance with, the requirements of MIL-F-13926
specified below:
Order of precedence
a.
Dimensions and tolerances
c.
Inorganic protective surface finishes
d.
Part identification and marking
e.
Workmanship
Soldering electrical connections
f.
3.3 Environmental.
3.3.1 Storage temperatures.- The mount shall show no evidence of
physical failure such as casting failure, adhesive failure, deterioration
of the wiper blade, or deterioration of Gasket 10513302 due to storage
at temperatures ranging from -80 to +160 Fahrenheit (F). subsequent to
meetng this requirement, the mount shall be capable of meeting the re-
quirements of 3.5.