 |  MIL-M-70453A (AR) 4.7.8.1 Telescope Clamping mechanism. unlocked Position. When subjected to a tactile examination, the function of the locking lever shall meet the requirements of 3.8.1.1. When the mandrel is inserted into the telescope holder, it shall rotate freely for 360 degrees and the telescope holder move fore and aft freely. 4.7.8.2 Telescope clamping mech anism. lock ed position Insert the mandrel into the telescope holder.  Apply a force of 15 to 17 inch-pounds to the locking lever and 10 to 12 inch- pounds to the wing nut.  Apply the specified torques to the mandrel and telescope holder, in turn.  The Telescope clamping mechanism shall meet the reqirements of 3.8.1.2. Install and remove the mount 4.7.8.3  Mount locking latch from the dovetail on the stand a minimum of three (3) times (3 The mount shall meet the requirements of 3.8.2, installations). at the temperature specified. 4.7.8.4  Locking kn obs .  Rotate the azimuth and elevation locking knobs to a locked position with the appropriate torque wrench and adapter.  The azimuth and elevation mechanisms shall meet the requirements of 3.8.3 when the specified torque is applied to the applicable knob, at the temperature indicated. 4.7.8.5 Azimuth slip scales. When subjected to a tactile examination for operability, the micrometer knob slip scales (azimuth and elevation) and azimuth scale shall meet the requirements of 3.8.4, at the temperature indicated. This test shall be 4.7.8.6  Torque, coarse azimuth performed on complete M64A1 sight Mount Assembly (P/N 9360169) units.  The sight assembly shall be mounted via the dovetail such that it is possible to level the bubble vials using the azimuth and elevation knobs and with sufficient security to assure that the level will not change during the test.  The torque shall be applied in a uniformly increasing reamer at a rate not to exceed 1.0 inch-pound per second and the actual torque value at which the scale initially slips shall be recorded.  The test equipment shall not exert a force on the coarse azimuth scale in a downward direction greater than 1.1 pounds while the torque is being measured.  Prior to performing the test, the azimuth control knob shall be used to rotate the coarse azimuth scale at least 400 mils in the clockwise direction stopping with the O mil mark on the scale aligned with the index arrow.  The counterclockwise torque value should now be obtained.  The azimuth control knob should then be used to rotate the coarse azimuth scale 400 mils in the counterclockwise direction and the clockwise torque value should be obtained.  The coarse azimuth scale shall then be 23 | 
| 
 Privacy Statement - Press Release - Copyright Information. - Contact Us |