| MIL-M-70779 (AR)
APPENDIX A
40.2.2 System operating current. The system operating current shall b
measured by connecting the S.U.T as shown in Figure 2. Input
shall have
fifteen-hundred (1,500) fast counts applied with SW1 closed. Open
one-hundred (100) milliseconds minimum and measure operative current.
Operating current must meet the requirements of Table II.
Operating current measurement.
Figure 2.