MIL-M-70779 (AR)
APPENDIX A
40.2.13 Capacitor clamp time delay measurement.  The capacitor clamp time
delay shall be measured by connecting the S.U.T. as shown in Figure 12.
Before closing
shall be clocked for 20 seconds minimum.
will then be opened and
closed.
is closed, the timer will start counting, and will continue to
When
count, until
rises above 0.8 volts at which time the voltage comparator
will stop the timer.  The time delay measured must meet the requirements for
Normal Time Delay in Table II.  To measure Short Time Delay, close SW3 before
starting test.