3.4.5.4.5
Rigging. - Step-by-step procedures skill be included for
complete rigging of a system or subsystem.
3.4.5.4.6
Adjustment. - Step-by-step procedures shall be provided
for any alignments or adjustments required as a result of replacement of any
equipment or as required to determine that the system meets prescribed stand-
ards.
3.4.5.4.7
Extreme Environmental Conditions. - Specific instructions
for any precautions to be observed or special maintenance required under ex-
treme environmental conditions shall be included.
3.4.5.4.8
Engine Buildup Instructions. - The power plant manual
shall include instructions for installing components on the nude or basic air-
craft engine. These instructions shall be compatible with engine installation
and removal procedures to assure that engines are built up to the proper point
for engine installation in the aircraft.
Quick Engine Change (QEC) Units. - Engine buildup in-
3.4.5.4.8.1
structions shall contain information on applicability and interchangeability of
QE C units, preparation for engine buildup and ground handling of engines.
Component Installation. - Step-by-step installation of com-
3.4.5.4.8.2
ponents to build up a nude or basic engine for all aircraft configurations and all
engine positions shall be provided and illustrated as necessary for clarity. The
effect of engine position on component arrangement shall be provided for each
component by nomenclature, quantity per assembly and installation sequence.
The instructions shall be broken down into separate installations to facilitate build-
up of an engine in the most logical sequence. (see figure 10 for an example of
presenting step-by-step buildup instructions. )
Wiring Diagrams. - This coverage shall contain electrical
3.4.6
and electronic wiring diagrams and data necessary for clarification of inter-
component power, control, and signal circuits and for circuit tracing, continuity
checks, and troubleshooting between components. Internal circuits of components
shall not be shown when component circuits are included in separate manuals
or the functional system schematic(s). When applicable and technically feasible,
diagrams furnished shall be direct reproductions of engineering drawings for the
installations and equipment concerned, and shall reflect the delivered equipment.
Any data not required by the contract drawing specifications which may have
been included on the drawings for the contractor's own purposes shall be deleted.
Introduction. - An introduction prepared in accordance with
3.4.6.1
MIL-M-387M shall be provided