| MIL-N-85005A(AS)
-
*3.5.3.6 Electrical Connections - Connections to external circuits
shall be provided as listed.
Reference
Function
Receptacle Type
Designation
Digital Displays
SJTP02RE18-35PA(023)
J1
Logic Power
System Power - The equipment shall utilize system power
3.5.3.7
from the Keyer Control as follows:
(1) 115 VAC, 400 Hz, 1 0, Category B, 0.004 Amps
(2) 0 - 5 VAC, 400 Hz, 1 0, 0.6 Amps
(3) 6 VDC, 6.5 Amps.
(4) 5 VDC, regulated, 2.6 Amps.
Mounting - Chassis and mounting requirements of MIL-C-6781
3.5.3.8
and MS25212 shall apply.
Color - Surface shall be painted lusterless gray, No.
3.5.3.9
36231 in accordance with FED-STD-595.
Control, Marker Plotter C-9855/ASN-124 - The Control
3.5.4
shall meet the following requirements:
Function - The Control is used by the pilot to control
3.5.4.1
the entry and display of data on the Tactical Data Display IP-886/MA-66
(or equivalent). It includes the symbol generator circuits which drive
that Display.
Form Factor - The Marker Plotter Control, exclusive of
3.5.4.2
front panel protrusions, attachment points, and connector projections,
shall be formed within the following maximum dimensions (inches).
Width
Depth
Height
9.000 (behind mount-
5.750
5.250
ing surface)
- 50 -
|