| MIL-O-8114B(OS)
4.4.4.9.4 Remove the wave analyzer test leads and secure the power to
the test equipment and power supply.
4.4.4.1O Visual and dimensional examinations. Each oscillator shall
be examined to determine conformance with the requirements for work-
manship and dimensions.
4.4.4. 11 Packaging, packing) and marking. Packaging, packing, and
marking shall comply with the requirements of Section 5.
4.5 Reproduction and periodic production inspection. The preproduc-
tion and periodic production samples, after satisfactorily passing the
quality conformance inspections detailed in 4.4, shall be subjected to
the following tests and examinations. Certified inspection data covering
the results of preproduction and periodic production inspections shall be
forwarded to the procuring activity.
4.5.1 Vibration
4.5.1.1 Mounting. The oscillator subassembly, less pack or packaging,
shall be mounted to a test fixture as shown in Figure 3 and tested as
specified in 4.5.1.2 and 4.5.1.3.
4.5.1.2 Vibration, nonoperating. The oscillator subassembly shall be
subjected to the "Vibration, nonoperating" test of MIL-E-82590 and there-
after shall meet the requirements of 3.5.1.1.
4.5.1.3 Vibration, operati ng. The oscillator subassembly shall be
subjected to the "Vibration, operating" test of MIL-E-82590 and during
and thereafter shall meet the requirements of 3.5.1.2.
4.5.1.4 Vibration, transportation. The oscillator subassembly shall
be subjected to the "Vibration, transportation" test of MIL-E-82590 and
thereafter shall meet the requirements of 3.5.1.3.
4.5.2 Shock, transportation. The oscillator subassembly shall be sub-
jected to the "Shock, transportation" test of MIL-E-82590 and thereafter
shall meet the requirements of 3.5.2.
4.5*3 Temperature and humidity
4.5.3.1 High temperature and humidity, nonopera ting. The oscillator
subassembly shall be subjected to the "High temperature and humidity,
nonoperating" test of MIL-E-82590 and thereafter shall meet the requie-
ments of 30503.10
4. 5.3.2 High temperature, operating. The oscillator subassembly shall
be subjected to the "High temperature, operating" test of MIL-E-82590 and,
while at the test temperature, shall meet the requirements of 3.5.3.2.
13
|