| MIL-P-46610E(MU)
Primers to be used in spotter-tracer cartridges will be tested for function
and casualty in the caliber .50 cartridge, Drawing C7553097. When components
for the caliber .50 cartridge, Drawing C7553097 are not available, spotter-
tracer cartridge, Drawing C8594735, shall be used.
4.4.3.1 Reduced testing.-Function and casualty firing may be reduced in
acceptance testing if five consecutive lots, all using the same primer mix and
production process, have met the requirements of 3.4. The reduced plan shall
consist of testing one out of every five lots submitted. Testing of every lot
shall be resumed when the requirements of 3.4 are not complied with or when
the primer mix or production process changes.
4.4.4 Velocity.-The primer shall be inserted and crimped in cartridge
cases. The primed cases shall be assembled into cartridges and then tested in
accordance with TECP 700-700, Vol. III; AMCR 715-505, Volumes 3 and 5, or
AMSMU-P-715-501FA1 as applicable.
4.4.5 Chamber pressure.-The primer shall be inserted and crimped in
cartridge cases. The primed cases shall be assembled into cartridges and then
tested in accordance with TECP 700-700, Vol. III; AMCR 715-505, Volumes 3 and
5, or AMSMU-P-715-501FA1 as applicable.
4.4.6 Priming composition analysis. -The analysis shall be made using
standard laboratory practices and procedures.
18
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |