MIL-P-4845lA(MU)
TABLE IV
TEST PROCEDURE
REQUIREMENT
CHARACTERISTIC
No.
4.6.1.1
3.4.1
304. Storage temperature
(-80 and +160F)
4.6.1.2
3.4.2
305. Operating temperatures
o
(-40 and +150 F)
4.6.1.2, 4.6.2.1
306. Operability, elevation input shaft
3.4.2, 3.5.1
4.6.1.2, 4.6.2.2
3.4.2, 3.5.2
307. Operability, diopter movement -
Daylight and Passive
4.6.1.2, 4.6.2.3
308. Operability, focusing mechanism -
3.4.2, 3.5.3
Passive
4.6.1.2, 4.6.2.4
309. Operability, disengagement of bore-3.4.2,
3.3.4
sight knob locks - Daylight
and Passive
4.6.1.2, 4.6.2.5
310 l Operability, rotation of boresight 3.4.2,
3.5.5
knob - Daylight and Passive-
4.6.1.2, 4.6.2.6
3.4.2,
3.5.6
311 l Operability, shutter lever and
on-off  switch l Passive
4.6.1.2, 4.6.2.7
312. Operability, gain adjust and re- 3.4.2,
3.5.7
ticle brightness control - Passive
NOTE:
The tests for characteristics 306 through 312 inclusive, shall be
conducted at -40 and +150F.
4.4.4 Failure of sample.- Should any one Item of a special sampling
fail to meet the specified test requirements, acceptance of the represented
inspection lot shall be suspended by the Government until necessary correc-
tions have been made by the contractor and resubmitted samples have been
approved (see 4.3.3).
4.5 Inspection equipment.- Except as otherwise provided for by the
contract, the contractor shall supply and maintain inspection equipment
in accordance with the applicable requirements of MIL-I-45607.
4.5.1 Government furnished inspection equipment.- Where the con-
tract provides for Government furnished test equipment, supply and maint-
enance of test equipment shall be in accordance with the applicable re-
quirements specified in MIL-I-45607.
4.5.2 Contractor furnished inspection equipment.
4.5.2.1  Goverment design.- Unless otherwise specified in the con-
tract, all inspection equipment specified by drawing number in specifica-
tions or SQAP forming a part of the contract shall be supplied by the con-
tactor in accordance with technical data listed in the technical data
package (TDP).
11