| ![]() MIL-P-48571(MU)
104.
(Operability,-disengagement of
boresight knob locks - Daylight
and Passive
3.5.4
4.6.2.4
105.
Operability, rotation of bore-
sight knob - Daylight and
Passive
305.5
4.6.2.5
106.
Operability, shutter lever and
on-off switch - Passive
3.5.6
4.6.2.6
107.
Operability, gain adjust and
reticle brightness control -
Passive
3.5.7
4.6.2.7
108.
Operability, focusing lock -
Daylight
3.5.8
4.6.2.8
109.
Operability, objective
focusing mechanism - Daylight 3.5.9
4.6.2.9
110.
Collimation pre-vibration
setting
3.8.3.1
4.6.3.1
111.
Vibration "B"
3.6.2
4.6.3.3
112.
Post-vibration examination
3.6.2
4.6.3.5
113.
Post-vibration- collimation
3.8.3.2
4.6.3.6
114.
Cleanliness
3.7
4.6.5
115.
Parallax
3.8.2
4.6.6.2
116.
Elevation knob travel,
daylight viewing area
3.8.3.1.1a
4.6.6.3.1
117.
Deflection knob travel, day-
light viewing area
3.8.3.1.1b
4.6.6.3.2
118.
Elevation knob travel, passive
viewing area
3.8.3.1.2a
4.6.6.4.1
119.
Deflection knob travel, passive
viewing area
3.8.3.1.2b
4.6.6.4.2
120.
Collimation repeatability
assembling daylight body to
head assembly
3.8.4.1
4.6.3.1.1
121.
Collimation repeatability,
assembling passive elbow to
head assembly
3.8.4.1
4.6.3.7.2
122.
Image tilt, daylight and passive 3.8.5
4.6.6.5
parallelism of reticle and
123.
image, passive
3.8.6
4.6.6.6
124.
Parallelism of reticle and
image, daylight
3.8.6.1
4.6.6.6.1
Objective focusing range,
125.
daylight
3.8.7.1
4.6.6.7.1
Objective focusing range,
126.
passive
3.8.7.2
4.6.6.7.2
MINOR: NONE
The tests in Table I shall be conducted at a temperature between
NOTE:
+60 and +90F.