| ![]() MIL-P-48619(AR)
TABLE II - CLASSIFICATION OF DEFECTS - CONTINUED
TEST PROCEDURE
REQUIREMENT
CHARACTERISTIC
CLASS
CRITICAL: NONE
MAJOR: AQL 0.65% Defective
4.6.2.3
3.5.3
112. Operability, focusing
mechanism - Passive
4.6.2.4
3.5.4
113. Operability, disengagement of
boresight knob locks -
Daylight and Passive
4.6.2.5
3.5.5
114. Operability, rotation of bore
sight knob - Daylight and
Passive
4.6.2.6
3.5.6
115. Operability, shutter lever and
on-off switch - Passive
4.6.2.7
3.5.7
116. Operability, gain adjust and
reticle brightness control -
Passive
4.6.2.8
3.5.8
117. Operability, focusing lock -
Daylight
4.6.2.9
3.5.9
118. Operability, objective
focusing mechanism Daylight
4.6.3.1
3.8.3.1
119. Collimation pre-vibration
setting
4.6.3.3
3.6.2
120. Vibration "B"
4.6.3.4
3.6.2
121. Post-vibration examination
4.6.3.5
3.8.3.2
122. Post-vibration collimation
4.6.5
3.7
123. Cleanliness
4.6.6.2
3.8.2
124. Parallax
4.6.6.3.1
3.8.3.1.1a
125. Elevation knob travel,
daylight viewing area
4.6.6.3.2
3.8.3.1.1b
126. Deflection knob travel,
daylight viewing area
4.6.6.4.1
3.8.3.1.2a
127. Elevation knob travel, passive
viewing area
4.6.6.4.2
3.8.3.1.2b
128. Deflection knob travel, passive
viewing area
4.6.3.6.1
3.8.4.1
129. Collimation repeatability,
assembling daylight body to
head assembly
4.6.3.6.2
3.8.4.1
130. Collimation repeatability,
assembling passive elbow to
head assembly
4.6.6.5
3.8.5
131. Image tilt, daylight and
passive
4.6.6.6
3.8.6
132. Parallelism of reticle and
image, passive
14
|