MIL-P-63334(AR)
TABLE I - R1 PERFORMANCE
Primary
Rheostat Wiper
Circuit Load
Arm Position
Rheostat
Power
DC amps
30 VDC
R1
extreme CW - Min. Res.
.28 .04
R1
30 VDC
extreme CCW - Max. Res.
.185 .01
30 VDC
OFF
R1
.122 .01
3.6.1.2 Rheostat R2.  Rheostat R2 output circuit shall exhibit the vol-
tage specified in Table II for each respective circuit under the specified DC
load conditions, rheostat arm positions, and applied battery power, Switch S1
shall be in the "Emergency" position and switch R2 shall be operated.
TABLE II - R2 PERFORMANCE
Rheostat Wiper
Primary
Circuit Load Circuit Out-
Arm Position
Rheostat
Power
DC amps  puts DC volts
.700
6 VDC
5.6 .4
R2
extreme CW - Min. Res.
6 VDC
1.7 .2
R2
extreme CCW - Max. Res.
6 VDC
OFF
R2
Zero
3.6.1.3 Output of voltage regulated supplies.  The battery charging,
reticle projector, and high voltage oscillator supplies shall exhibit the vol-
tage regulation specified in Table IV.  This regulation shall exist over the
indicated primary power source voltage and under the specified DC load condi-
tions.  The reticle projector and high-voltage oscillator outputs in Table IV
shall only be available with Switch S1 in the "ON" position and after switch
S2 has been operated.
With S1 in the "OFF" position Terminals J1-K and J1-L shall exhibit zero vol-
tage relative to all ground terminals.