| MIL-P-70624A(AR)
3.6.2.1 Self check liqht bulb test. The Ready Light and Fail
Light shall come on when tested as specified in 4.5.4.3.
3.6.3 Electronics box assembly. The power outputs shall
follows when tested as specified in 4.5.4.3.
Voltage
Pin
131
TB 3-1(-) and TB 3-9(+)
3.6.4 Electronics box assembly. The power outputs and
observations shall be as follows when tested as specified in 4.5.4.4.
Voltage
Pin
READY light is ON
1.
FAIL light is OFF
2.
26 .5
TB 3-1(-) and TB 3-3(+)
3.
21 1
TB 3-1(-) and TB 3-2(+)
4.
10 1
TB 3-1(-) and TB 3-5(+)
5.
13 1
TB 3-1(-) and TB 3-8(+)
6.
Less than 1 volt
TB 3-1(-) and TB 3-9(+)
7.
TB 3-1(-) and TB 3-10(+)
26 .5
8.
TB 3-1(-) and TB 3-11(+)
4 1 AC
9.
5.2 to 5.4 volts @
TB 3-1(-) and TB 3-12(+)
10.
trigger (for
information only).
3.6.4.1 Ready light test. The ready light shall brighten or
become dim when tested as specified in 4.5.4.5a.
3.6.5 Electronics box assembly. The READY light shall go off
and come on in less than ten (10) seconds when the proximity switch
is activated as specified in 4.5. 4.5,b.
3.6.6 Electronics box assembly. The READY light shall stay on
and the FAIL light shall come on and stay on after the transmitter
coil is disconnected and the prox switch is activated as specified
in 4.5.4.6.
3.6.7 Electronics box assembly. The READY light shall come on
and the FAIL light shall be off when the Transmitter Assembly is
connected to J2 on the electronics box as specified in 4.5.4.7.
The READY light shall go off
3.6.8 Electronics box assembly.
not come on. The output of
and stay off and the FAIL light shall
the transmitter shall be -9 2 volts
on the oscilloscope as shown
in Figure 1 when tested as specified
in 4.5.4.8.