| MIL-P-70624A(AR)
3.6.9 Electronics box assembly. The power outputs and
observations shall be as follows when tested as specified in 4.5.4.9.
Voltage
Pin
READY light is ON
1.
FAIL light is OFF
2.
261
TB 3-1 and TB 3-3
3.
211
TB 3-1 and TB 3-2
4.
441
TB 3-1 and TB 3-5
5.
13l
TB 3-1 and TB 3-8
6.
Less than 1 volt
TB 3-1 and TB 3-9
7.
261
TB 3-1 and TB 3-10
8.
4 1 AC volts
TB 3-1 and TB 3-11
9.
5.2 to 5.4 volts @
TB 3-1 and TB 3-12
10.
trigger point for
(for information
only.)
3.6.10 Electronics box assmbly. The READY light shall go off
and stay off and the FAIL light shall stay off. The output shall be
33 3 volts on the oscilloscope as shown in Figure 2 when tested as
specified in 4. 5.4.10.