MIL-P-82436(OS)
TABLE IV
3.4.4
Tempe rature and humidity.
Non-operating.
3.4.4.1
a.
Temperature.
The pump shall be capable of meeting the
performance requirements subsequent to withstanding, in
the non-operating condition, environmental temperatures
between -45 F and +140 F.
Temperature is defined in
6.3.7.
Humidity.  The pump shall be capable of meeting the
performance requirements subsequent to withstanding, in
the non-operating condition, an environment of at least
95 percent relative humidity at +110 F for a minimum
period of 8 hours.  Humidity is defined in 6.2.8.
3.4.4.2
Ready, operating,  The pump. immediately after being condi-
F and
F shall be
tioned for 1 hour at any temperature between
capable of meeting the performance requirements at any envirommental
temperature between 0 F and +140 F.
3.5
Operational service life.  The pump shall have a minimum
service life of 70 minutes which shall be divided into 10 cycles of 7
minutes each.