MIL-P-82436(OS)
Periodic production sample.
Periodic production samples
4.3.2
shall be selected from units that have satisfactorily passed the accept-
These samples shall be subjected to the tests
ance inspections of 4.5.
of 4.6 at an activity designated by the procuring activity.  Periodic
production sampling shall be as follows:
Upon initiation of production randomly select 1
Step 1.
unit from each group of 30 units.  Upon satisfactory compliance
of samples selected from 3 consecutive groups, shift to Step
2.
Randomly select 1 unit from each group of 70
Continue with Step 2 for the balance of the contract
or until a defective unit is found.
When a defective unit is found in any group, acceptance of all units on
hand shall be withheld and the contractor shall:
Determine the cause of the defect.
Take the necessary actions to correct or eliminate the
defect from all units on hand and, if so directed by
the procuring activity, from those units previously
shipped.
Submit to the procuring activity for approval, the
proposed corrective action to prevent recurrence of
the defect.
Submit to the procuring activity for approval the
proposed retest program to verify that the corrective
action eliminated the defect.
Return to Step 1 and proceed as indicated when inspection is resumed.
Examination of first echelon repair parts.  The sampling plans
4.3.3
and procedures set forth in MIL-STD-105 shall be used in the determination
of acceptability of first echelon repair parts for the pump as specified
in 4.7 through 4.7.4.
Preproduction inspe ction .
4.4
Tests and ex aminations .  The preproduction sample
of 3 pumps
4.4.1
shall be subjected to the operational test defined in 4.5.4.1
and sub-
sequently shall be inspected in accordance with Table V, with
1 pump
being tested in accordance with each of the 3 test sequences,
A through C.