| MIL-P-82442(OS)
TABLE IX
PERIODIC TEST SCHEDULE
* Visual Check After Testing
4.6.1
Test conditions. Unless Otherwise specified, the pump shall
be subjected to the periodic tests under the following conditions:
Temperature:
Room ambient +32 F to +98F
Altitude:
Normal ground atmospheric pressure
Vibration:
None
Humidity:
Room ambient
4.6.2
Test equipment and set-up. The test equipment and set-up for
the periodic tests shall be in accordance with 4.4.3.
4.6.3
Test procedures.
4.6.3.1
Vibration, ready condition. Vibration testing of the pump,
in the ready condition, shall be performed in accordance with 4.4.4.2.
4.6.3.2
Acceleration, ready condition. Acceleration testing of the
pump, in the ready condition, shall be performed in accordance with 4.4.4.3.
4.6.3.3
Shock, ready condition. Shock testing of the pump, in the
ready condition, shall be performed in accordance with 4.4.4.4.