| MIL-P-82534(OS)
Table III. Preproduction and Periodic Production Test Sequence (Continued)
4 . 3 . 4 Quality conformance inspection sampling. Each individual pro-
grammer shall be inspected as specified in 4.6.1 to determine its acceptability.
4.4 T e s t e q uipment and test conditions.
4 . 4 . 1 Quality conformance inspection equipment. The following items
of test equipment are required to perform the quality conformance inspection
tests:
Capability
Equipment
10 to 20,000 ohms; reading accuracy
a. Resistance measuring
of plus or minus 5 percent; applied
device
current limited to a maximum of 10
milliamperes
0.01 to 30.00 ohms; reading accuracy
b. Resistance measuring
device
of plus or minus 5 percent; applied
current limited to a maximum of 10
milliamperes
5 to 20 megohms; accuracy 5 percent
c. Megohmmeter
with 500 plus or minus 50 volts DC
potential