|
| MIL-P-82534(OS)
Equipment
Capability
d. Temperature chamber
Maintain temperature at:
Plus 35 plus 5 minus 0 degrees F
Plus 120 plus 0 minus 5 degrees F
e. Oscilloscope
5-inch diameter tube, triggered, cali-
brated sweep of 1 millisecond per
centimeter, rise time less than 1
microsecond; camera attached for
recording trace
f. Tester, Acceptance,
BuWeps LD 541505. Operate in accor-
Range and Airframe
dance with OD 12995.
Separation Programmer
g. Mass spectrometer
Minimum sensitivity of 10 to the minus
helium leak detector
sixth power cubic centimeters per
second of helium
4.4.2 Preproduction and p e riodic production test equipment. The following
items of test equipment, in addition to selected items of quality conformance
inspection equipment and pieces of equipment recommended by applicable speci-
fications or standards referenced within test procedure paragraphs, are required
to perform the preproduction and periodic production tests:
Capability
Equipment
a. Temperature chamber
Maintain temperature at:
Minus 65 plus 5 minus 0 degrees F
Plus 35 plus 5 minus 0 degrees F
Plus 120 plus 0 minus 5 degrees F
Plus 160 plus 0 minus 5 degrees F
b. Shock equipment
Apply shocks of 40 plus or minus 4g
peak magnitude; a one-half sine wave
pulse shape of 5 plus 3 minus 0 milli-
seconds time duration; maintain direc-
tion along specified axes
c. Vibration testing
Control frequency from 20 to 2000 cps
machine
while subjecting the test item to 0.10-
inch double amplitude or 10g accelera-
tion, whichever is less; maintain direc-
tion of vibration along specified axes
d. Centrifuge
0 to 27.5g; maintain acceleration at
25 plus 2.5 minus 0g
12
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |