| MIL-P-8258D(AS)
shall be one shipping
same materials and components. The sample unit
container, containing pumps fully prepared for delivery, except that it
need not be sealed.
Test conditions. Unless otherwise specified, all
4.5
atmospheric
tests required by this specification shall be made at an
, and
pressure of 28 to 32 inches of mercury and a temperature
Where tests are made with
a relative humidity of 80 percent or less.
atmospheric pressure or temperature substantially different from the
above values, proper correction of test results shall be made for the
change in instrument readings.
Examinations.
4.6
Every pump shall be examined visually for
4.6.1
Pumps.
Every
major defects to determine conformance to this specification.
pump selected as a sample unit from the lot shall be examined visually
for minor defects. Table II shall be used to classify the defects
found .
Classification of defects for the visual examination of the pumps
TABLE II.
MINOR
MAJOR
Surface unclean or containing
201.
1.
embedded foreign matter.
Markings missing, insufficient,
202.
illegible, not permanent, or
2.
misplaced .
3.
4.
5.
6.
7.
8.
7
|