| MIL-P-8258
The pumps and hoses shall be examined to
Dime-- ions.
--. ns
4.6.2
as specified herein.
determine if the dimensions are
Each of the fully prepared
Preparation for delivery.
4.6.3
shipping containers, containing pumps selected as sample units from the
lot, shall be visually examined to determine that the packaging, packing
Table III shall be used to
and marking conform to this specification.
classify the defects found.
Tests.
4.7
Each pump shall be tested for air discharge
Operation.
4.7.1
by moving the handle several times through the complete normal cycle of
operation.
List of defects for preparation for delivery
TABLE III.
DEFECT
ITEM
Missing, incorrect, incomplete, illegible;
Exterior and interior
of improper size, location, sequence, or
markings
method of application; markings on the
interior
or exterior containers not the same.
Any
nonconforming
component;
component
Materials
missing,
damaged,
or otherwise defective.
Inadequate application of the components,
Workmanship
such as incomplete closure of the film bag,
container flaps, loose strapping, etc.;
bulging or distortion of the containers.
Number per container is more or less than
Content
contains pumps of more than one
required;
type .
An airtight bag that, as nearly as
Air discharge.
4.7.2
. ractical, has had all the air removed from within shall be connected to
p
With the bag connected, the pump shall be operated
the outlet of the pump.
The amount of air discharged per stroke shall
at least 10 full strokes.
be determined by dividing the volume of the inflated bag by the number of
strokes.
The pump shall be exposed to a
Discharge at 70F.
4.7.2.1
temperature of 70F for a minimum of 24
hours and while still at this
The discharge
temperature the pump shall be tested as
specified in 4.7.2.
of air per stroke shall be no less than
32 cubic inches.
.
10
|