MIL-P-8258D(AS)
4.7.7
Hose kinking.
The hose shall be bent around a
mandrel having a diameter equal to  10 times the outside diameter of the
hose and then maintained in this position and at 160F for 4 hours.
4.7.8
The hose shall be subjected to an
Hose leakage.
oil-free internal air pressure of 25 psi for a minimum of 30 seconds.
While this pressure is maintained,  the leakage shall be determined by
immersing the hose in water and observing  for a continuous breakaway of
Any
bubbles or by noting the drop in the internal pressure
noticeable  leakage shall be cause for rejection.
4.7.9
The pump and hose shall be subjected to
-- alt -
S
spray.
a 96-hour salt spray test in accordance with Method "811 of Fed. Test
Method Std. No. 151.
After completion of this test, the pump and hose
shall be subjected to and pass the following:
(4.6.1)
Examination
of
pump
(4.7.2.1)
b.
(4.7.3)
Operating  force
(4.7.4)
Pump  leakage
d.
PACKAGING
5.
Packaging.
5.1
Packaging shall be level A or C, as
specified (see 6.2).
Level A.
Each pump,  including hose, shall be heat
5.1.1
sealed within a snugfitting film bag of 0.0015 inch gage material
Each  pump,  prepared  as  aforementioned,
conforming to MIL-F-22191, Type I.
shall be preserved and cushioned in accordance with MIL-P-116, Method
Erich pump shall be packaged
No contact preservative is required.
IC-5.
within a snug; folding or set-up box conforming to PPP-B-566 or PPP-B-676.
Forty unit packages shall be packaged within a fiberboard container
confoming to PPP-B636, type CF, class weather resistant, grade V3c,
style RSC.
Closure and sealing of the containers shall be in accordance
All seams and joints shall be sealed
with the appendix to PPP-B-636.
with tape conforming to PPP-T-60.
The pumps shall he packaged to afford the
5.1.2
Level C.
minimim degree of protection necessary to prevent deterioration or
damage during shipment under normal environmental  conditions  and  commercial
modes of transportation.
Packing.
Packing shall be level A, B, or C, as
5.2
specified (see 6.2).
Shipping containers, insofar as possible, shall be
uniform in size and shape and-of minimum cube and tare weight.
.