| MIL- Q-45618F(MU)
Quadrant, Fire Control Elevation: M13AlC
F8286737
Quadrant, Fire Control Elevation: M13A2
F8619627
Quadrant, Fire Control Elevation: M13Al
F8642402
PACKAGING DATA SHEETS
Packaging of Quadrants, Fire Control,
7652218
M13A1 and M13A1C
Packaging of Quadrants, Fire Control,
8619627
M13A2, M13A3 and M13B1
(Copies of specifications, standards, drawings, and packaging data sheets
required by suppliers in connection with specific procurement functions
I
should be obtained from the procuring activity or as directed by the
contracting officer.)
3.
REQUIREMENTS
3.1 Materials.- Materials shall be in accordance with drawings,
material specifications, and general specifications forming a part of
this specification.
3.2 Fabrication.- The quadrant shall be manufactured in accordance
with the drawing applicable to the type quadrant specified in the con-
tract and drawings pertinent thereto.
3.3 General specification.- The contractor shall be responsible
for adherence to, and compliance with, the following requirements of
MIL-F-13926.
Order of precedence
a.
Dimensions and tolerances
b.
Inorganic protective surface finishes
c*
Part identification and marking
d.
Workmanship
e.
3.4 Environmental.
3.4.1 Operating temperatures.- The quadrant shall meet the require-
ments of 3.6.4 while exposed to and thermally stabilized at ambient
o
temperatures of -40 F and +150F. Subsequent to this exposure, the
quadrant shall be thermally stabilized at standard ambient temperatures
{+60 to +90F), and shall meet the requirements of 3.4.2 and 3.6.
temperatUre.- The quadrant shall show no evidence of
3.4.2 Storage
physical failure such as casting failure or glass breakage and shall
I
meet the applicable requirements o of this specification at a standard
ambient temperature of 60 to 90 F after having been exposed to and
thermally stabilized at -80 and +160F.