MIL-Q-50385 (MU)'
4.3.2.2 Final acceptance inspection.- Subsequent to first article
approval, examination and tests related to Section 3 herein shall be per-
formed on a single defect (individual characteristic) basis in accordance
with MIL-STD-105 anti -the sampling. plans specified in Table I herein.
EXamination and tests for Packaging, Packing and Marking shall be in accord-
ance with MIL-P-14232 and Section 5 herein.  The tabulated classification of
defects in Table I shall constitute the minimum inspection to be performed
by the supplier after first article approval and prior to Government accept-
or rejection by item or lot.
TABLE I - CLASSIFICATION OF DEFECTS
TEST PROCEDURE
REQUIREMENT
CHARACTERISTIC
CLASS
CRITICAL: NONE
MAJOR:
3.4.3
4.6.2.1
101.
Post vibration physical condition
4.6.2.1
3.4.3
102.
Previbration physical condition
3.8.1
4.6.2.4
103.
Accuracy of elevation counter (limits)
4.6.2.3
3.7.1
Accuracy of elevation counter
104.
readings to quadrant pads
3.7.2
4.6.2.3
105
Crosslevel vial accuracy
q
4.6.2.5
3.7.3
106.  Correction counter operation and
accuracy
4.6.2.7
3.7.4
107.  Crosslevel cant limits
3.7.5.1
4.6.2.8
108.  Boresight adjustment (elevation)
4.6.2.9
3.7.5.2
109
Boresight adjustment (azimuth)
q
3.7.6.1
4.6.2.3
110.  Backlash elevation mechanism
4.6.2.7
3.7.6.2
111.  Backlash crosslevel mechanism
4.6.2.6
3.8.2
112.  Correction counter limit stops
3.10
4.6.2.11
113
Torque elevation knob
q
4.6.2.11
3.10
114.  Torque correction knob
3.10
4.6.2.11
115.  Torque crosslevel knob
4.6.2.11
3.10
116.  Torque boresight adjustment screws
3.11.1
4.6.2.12.1
117
Illumination counter
q
3.11.2
4.6.2.12.2
118.  Illumination level vial
MINOR:
3.9
4.6.2.10
201.
Counter digit alignment
4.4 Special sampling for environmental testing.
4.4.1 Samples shall be selected from lots at random from lots in
accordance with inspection Level S-3, Table I of MIL-STD-105. Acceptance
or rejection of the lot shall be in accordance with AQL 2.5 of Table II-A
of MIL-STD-105.  The samples shall have met a11 the requirements and tests