| MIL-Q-50386(MU)
4.4 Special sampling.
4.4.1 General.- Three quadrants shall be selected at random as a
special sampling from each 100 produced. The samples shall meet the
requirements and tests in Table II.
TABLE II
TEST PROCEDURES
NO.
REQUIREMENT
CHARACTERISTIC
3.1
Certification
301.
Regulations pertaining to
radioactive devices
3.2
Drawings - Visual
Fabrication
302.
3.3
MIL-F-13926 - Visual
General specification
303.
NOTE :
The tests in Table II shall be conducted at a standard ambient
temperature of between 60 and 90F.
Three quadrants shall be selected at
4.4.2 Environmental tests.-
random from each 50 produced, or from each month's production, whichever
occurs first. Each sample shall meet the requirements and tests in Table
III and shall then meet the requirements in Table I.
TABLE 111
TEST PROCEDURE
REQUIREMENT
CHARACTERISTIC
NO.
3.4.1
4.6.1
Storage temperatures
304.
4.6.2
3.4.2
305.
Low temperature operation
0
(-40 F)
4.6.2
3.4.2
306.
High temperature operation
0
(+150 F)
4.4.3 Failure of sample.- Should any item of a special sampling
fail to meet the specified test requirements, acceptance of the pro-
duct will be suspended by the Government until necessary corrections
have been made by the contractor and the resubmitted samples have been
approved (see 4.3.3).
4.5 Inspection equipment.- Except as otherwise provided for by
the contract, the contractor shall supply and maintain inspection equip-
ment in accordance with the applicable requirements of MIL-I-45607.
4.5.1 Government furnished inspection equipment.- Where the contract
provides for Government furnished test equipment, supply and maintenance
of test equipment shall be in accordance with the applicable requirements
specified in MIL-I-45607.
5
|