MIL-R-23016(Wep)
(Continued)
3.1.5.3
instruments (meters), encapsulated assemblies, and the like, in
which it is extremely unlikely that additional circuits will  be
required:
(a)
Extra unused connector contacts for external circuits of the
total specified below shall be available for future use by
the procuring activity.
(b)
The minimum quantity of extra unused contacts shall be as
follows. Approval of the procuring activity hall be ob-
tained if this requirement necessitates an additional con-
nector.
Extra
Total No. of Connector
Contacts
Pins in Major Assembly
2
Up to 25
4
26 to 100
6
101 or over
(c)
Size of extra contacts shall be compatible with other sizes
of contacts within the connector.
(d)
Each unused contact of the quantity specified herein shall
be rated at service A or higher voltage, as specified in
Specification MIL-C-5015.
(e)
Each connector shall provide sufficient pins for the ground-
ing of shields.
Special Contacts and Connectors:
3.1.5.4
All connectors used in conjunction with thermocouples shall be
markd by a securely fastened nameplate indicating the type of pin
metal, i.e. for chromel-alumel temperature sensing, nameplate should
read CR-AL.  Each pin of the connector shall be designated as to the
type of metal by suitable markings on the face of the connector.
3.1.5.5
Moisture and Fungus Resistant Treatment of Power and Miscellaneous
Connectors: