| ![]() MIL-R-23016(Wep)
3.1.3.5
Mounting of Fixed Capacitors:
Fixed capacitors shall be securely mounted. They shall not be
mounted by means of wire leads unless other mechanical support is
provided for the body of the capacitor, except that capacitors
whose weight does not exceed 1/2 ounce may be secured by only
their leads if the total length of both leads from a capacitor
to the terminals to which the leads are secured does not exceed
1 inch. In no case shall the tire leads be less than 1/8 inch
for capacitors with axial leads.
3.1.4
Castings:
In the design of castings, consideration shall be given to the
intended application, the availability of molding and casting
alloys, and to the choice of a suitable casting process. If re-
quired by 3.1.11, castings, whether impregnated or not, shall be
given conditioning treatments, and shall be processed to with-
stand corrosion.
Connectors:
3.1.5
3.1.5.1
Connectors for Voltmeter or Millimeter Measurements:
Connectors for voltmeter or millimeter measurements shall
accommodate a test prod having a diameter of 0.078 0.002 inch
and a maximum length of 7/16 inch.
3.1.5.2
Connector Wiring:
Pins shall be wired according to the following precedence:
(a) To reduce to satisfactory level, input to output coupling.
(b) To reduce to satisfactory level, noise coupling.
(c) To hold voltage gradient below service ratings of the appli-
cable cable connector specification.
3.1.5.3
Extra Contacts In Connectors:
The following requirements are applicable to all articles of equip-
ment, except those such as dynamotors, inverters, indicating