Toggle Switches:
3.1.25.4
The mounting of the toggle switches shall be such that the handle
of the switch operates in the length (vertical) direction of the
panel. Any "OFF" position shall be in the center or bottom
position. When clarification of a control function or convenience
of operation would result (for example, a "left-right" function
control), toggle switches may be so mounted that the handle of
the switch operates in the width direction of the control panel.
Terminals:
3.1.26
Terminals Attached to Parts:
3.1.26.1
Terminals attached to parts shall be mechanically strong and
shall not break when soldering and unsoldering connections there-
to. Terminals of potted parts shall be designed and fastened to
a terminal insulating strip or plate (or the enclosure itself,
if this complies with the insulation requirements) in such manner
as not to cause any degradation in the moisture excluding property
of the enclosure by normal soldering and resoldering of the
external leads to the terminals. Terminals shall be so spaced
as to assure a leakage resistance sufficiently high and to
insure safe creepage distances for the particular application
under specified conditions of high humidity and altitude.
Insulating barrier covers or strips shall be provided over all
exposed terminals contained within the equipment where possibil-
ity of contact with dangerous voltage exists.
3.1.26.2
Terminals Attached to Wires:
Terminals attached to wires shall be of a solder or solderless
type.
3.1.26.3
Terminal Spacing:
Adequate terminal spacing or barriers shall be employed to pre-
vent corona or breakdown or low-leakage resistance under high
humidity, including condensation, and under high-altitude
conditions.
3.1.27
Threaded Parts:
Threaded parts shall be of sufficient size to insure adequate
strength for the intended use.