| MIL-R-39016/32F
Overload (high level only):
Resistive: Two times rated current.
Inductive: Two times rated current.
Neutral screen: Applicable.
Coil data: (See table I.)
Duty rating: Continuous (one coil at a time).
Operate time (each coil): 5 ms maximum over temperature range.
Release time: Not applicable.
Electrical data:
Insulation resistance: 1,000 megohms minimum, except the resistance between coil and case at high
temperature shall be 500 megohms or greater.
Dielectric withstanding voltage:
Sea level:
Between case, frame, or enclosure, and all contacts - - - - - - - - - - -
1,000 V rms (60 Hz)
Between case, frame, or enclosure, and coil(s) - - - - - - - - - - - - - -
500 V rms (60 Hz)
Between all contacts and coils - - - - - - - - - - - - - - - - - - - - - - - - - -
1,000 V rms (60 Hz)
Between open contacts in the latch and reset positions - - - - - - - - -
500 V rms (60 Hz)
Between coils - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1,000 V rms (60 Hz)
Between contact poles - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1,000 V rms (60 Hz)
Altitude:
Between all terminals to case - - - - - - - - - - - - - - - - - - - - - - - - - - -
350 V rm (60 Hz)
Environmental data:
Temperature range: -65C to +125C.
Magnetic interference: Not applicable.
Vibration (sinusoidal): Method 204, MIL-STD-202. Contact chatter shall not exceed 10 s maximum for closed
contacts, and 1 s maximum closure for open contacts.
Vibration (random): Method 214, MIL-STD-202, test condition IG. Contact chatter shall not exceed 10 s
maximum for closed contacts, and 1 s maximum closure for open contacts.
Shock (specified pulse): Method 213, MIL-STD-202, test condition C (100 g's). Contact chatter shall not
exceed 10 s maximum for closed contacts, and 1 s maximum closure for open contacts.
Coil life: Not applicable.
Resistance to soldering heat: Applicable.
Acceleration: Applicable.
4
|