| ![]() MIL-R-39016/32F
REQUIREMENTS:
Contact data:
Arrangement: 2 form C.
Load ratings (relay case grounded):
High level:
Resistive: 2.0 amperes at 28 V dc; 0.15 ampere at 115 V ac, (60 Hz and 400 Hz).
Inductive: 0.8 ampere at 28 V dc (200 mH); 0.1 ampere at 115 V, 60 Hz and 400 Hz.
Lamp: 0.1 ampere at 28 V dc. 1/
Low level: 10 A to 50 A at 10 mV to 50 mV dc or peak ac.
Intermediate current: 50,000 cycles.
Contact resistance or voltage drop:
Initial: 0.050 ohm maximum.
High level:
During life: Maximum of 10 percent of open circuit voltage.
After life: 0.100 ohm maximum.
Low level:
During life: 50 ohms maximum.
After life: .150 ohm maximum.
Intermediate current:
During intermediate current: 1 ohm maximum.
After intermediate current: 0.300 ohm maximum.
Contact bounce: 1.5 ms maximum.
Contact stabilization time: 2.5 ms maximum.
1/ Contact resistance 3 ohms during and after life.
3
|