MIL-R-48595A(AR)
Power and signals.
TABLE I.
Condition
Characteristics
Electronic Unit Connections
Item
Connected between the
Power Source
1.0
following terminals:
24 6 Vdc
J4-A and B(+) lnd
Tank Power
1.1
J4-C end D (-}
Ripple: 200 mV max
246Vdc
Applied between J6-A (+)
1.2
Tank Power
Ripple: 200 mV p-p max .
and J6-L (-) when
specified herein.
Applied between J6-J (+)
15.0 0.7 Vdc
1.3
Plus 15 Vdc
and J6-L (-)
Ripple: 0.5 V p-p max
-15.0 0.7 Vdc
Applied between J6-K (-)
1.4
Minus 15 Vdc
and J6-L (+)
Ripple:
0.5 v p-pm
AC Ref 1
Applied between J6-Mand
1.5
5.000 0.010 Vrms
J6-L-
400 4 Hz
Applied between J6-N and
AC Ref 2
1.6
5.000 0.010 Vrms
400 4 Hz, also must be
J6-S
out-of-phase with AC
Ref 1 by 180 2.25
Applied between J6-P and
1.7
115.0 5.0 Vrms
115V, 400 Hz
J6-R when specified here-
400 40 Hz
in
2.0
Signal Source
5.0 0.5 Vdc
Applied between J7-R (+)
2.1
Remote reset/
and J7-N (-) when
range
specified herein
Applied between J6-W and
Analog O to
2*2
O to 36 Vrma, 400
J6-X when specified
40 Hz, must be in-phase
36 V
here-in
or out-of-phase with
115V, 400 Hz source of
item 1.7
3.3.1 Power turn-on condition.  With the EMER POWER switch set to the ON
position, the-following conditions shall exist at the commander's control
panel: (See 4.6.2.1)
a. The RANGE and RETURNS shall indicate zero.
b.
The RESET, FEED, LAST and BATTLE RANGE lamps shalI illuminate.
4