| MJL-R-50746(MU)
8 AUgUSt 1973
TABLE V
INSPECTION
EQUIPMENT
Description
Nomenclature
Item
1
D C Power Supply
+24 2 volts at 15 amps
Kipple: <200 mv p-p
Source impedance: <0.01~
D C Power Supply
2
+5. O O.2 Vdc
Ripple: <25 mV p-p
D c Power Supply
3
-6.0 O.2 Vdc
Ripple: <25mV
p-p
D C Power Supply
+15,0 0.7 Vdc
4
Ripple: <25 mV p-p
D C Power supply
Zero to +15 Vdc, adjustable
5
Ripple: <25 mV p-p
D C Power Supply
6
+29 1 Vdc
Ripple: <25 rnv p-p
D C Power Supply
7
-2100 50 Vdc
Ripple: <100 mV p-p
Range: o to 50 volts
D C Voltmeter
8
Accuracy: O.3 percent
Range: O to 100 microampere
D C Ammeter
9
Accuracy: *1 percent, meter resistance
4400
Oscilloscope with
Frequency response to 150 MHz
10
Camera
Sensitivity: 5 mV/cm
Sweep time: O. 01 psec/cm
Camera lens: f/1.3 (Tektronix C40 or
equivalent)
11
Thermo Pile*
TRG 108, Tekmar Instruments, Inc. or
equivalent
Energy Meter
12
TRG 113, Tekmar Instruments, Inc. or
equivalent
13
Signal Source
Capable of providing dc level as
specified in table I, item 3.1
*An equivalent for items 11 and/or 12 is model 580 Radiometer