| MIL-R-63997B(AR)
1
Rifles failing to meet the applicable requirement shall be
rejected.
2
Magazines may be used twice provided that excessive oil
and shop dirt are removed from the magazine prior to repackaging.
3
The cyclic rate of fire shall be taken and recorded on
each rifle until 190 consecutive rifles have met the cyclic rate
of fire requirement specified in 3.4.5.
When 190 consecutive
rifles on their initial test have met the cyclic rate of fire
requirement, every 10th rifle tested for function firing
requirements shall be tested for cyclic rate of fire requirement.
If a rifle fails to meet the cyclic rate of fire requirement
during sample testing of one of every ten, an additional sample of
ten rifles shall be tested for cyclic rate.
The 10 rifles tested
shall meet the cyclic rate of fire specified in 3.4.5.
If one or
more rifles fail to meet the requirements, the contractor shall
return to 100% testing of each rifle for cyclic rate of fire until
qualification requirements are met prior to returning to testing
one in ten rifles.
However, if the cyclic rate requirements for
the sample of ten rifles are met, the contractor shall continue
testing every 10th rifle for cyclic rate.
4
This test shall be
conducted
during
the
final
examination
specified in 4.5.2.1.
TABLE IV.
Inspection
lot
tests.
SAMPLE FOR
RESUBMITTED
REQUIRE-
TEST
TEST
1
SAMPLE
LOTS
MENTS
METHOD
3 24
I n d e n t2
Firing
Pin
32
3.4.2
4.7.2
Interchangeability
3.5
4.7.7
Inplant
1 04
Rifles
20
R e p a i r P a r t s5
5
10
Interplant
--
R i f l e s6
5
32
|