Click here to make tpub.com your Home Page

Page Title: Temperature, operating condition
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-R-81158A(WP)
4.5.4.2 Temperature, operating condition. The rear cover shall be sub-
jected to the following test procedure:
(a) Reduce the temperature to O degrees F plus or minus 5
degrees F (minus 17.78 degrees C plus or minus 2.78 degrees C) and after
maintaining this temperature for a -period of four hours, perform the
acceptance tests specified in 4.4.4.
(b) Increase the temperature to 40 degrees F plus or minus 5
degrees F (4.44 degrees C plus or minus 2.78 degrees C) in steps of 10
degrees F (5.56 degrees C) and stabilize for 30 minutes at each step.
After the 30-minute stabilizing period at 40 degrees F (4.44 degrees C)
perform the acceptance tests specified in 4.4.4.
(c) Increase the temperature to 70 degrees F plus or minus 5
degrees F (21.11 degrees C plus or minus 2.78 degrees C) in steps of 10
degrees F (5.56 degrees C) and stabilize for 30 minutes at each step.
After the 30-minute stabilizing period at 70 degrees F, perform the
acceptance tests specified in 4.4.4.
(d) Increase the temperature to 125 degrees F plus or minus 5
degrees F (51.7 degrees C plus or minus 2.78 degrees C) in steps of 10
degrees F (5.56 degrees C) and stabilize for 30 minutes at each step.
After the 30-minute stabilizing period at 125 degrees F perform the
acceptance tests specified in 4.4.4.
(e) Increase the temperature in steps of 10 degrees F (5.56
degrees C) stabilizing for 30 minutes at each step until 175 degrees F
plus or minus 5 degrees F (76.67 degrees C plus or minus 2.78 degrees C)
is reached.  Stabilize for at least four hours and perform the acceptance
tests specified in 4.4.4.
(f) Reduce the temperature to 80 degrees F plus or minus 5
degrees F (26.67 degrees C plus or minus 2.78 degrees C) in steps of 10
degrees F (5.56 degrees C) and stabilize for 30 minutes at each step.
the temperature to 68 degrees F plus or minus 5
(g) Reduce
degrees F (20 degrees
C plus or minus 2.78 degrees C) and stabilize for
at least four hours.
Immediately following this temperature cycle, the
rear cover shall meet
the performance and product requirements of this
specification.
4.5.5 Humidity, nonoperating condition.  The rear cover shall be sub-
jected to the following temperature cycle:
(a) Increase the temperature to 130 degrees F plus or minus 5
degrees F (54.44 degrees C plus or minus 2.78 degrees C) and the humidity
to 95 percent plus or minus 5 percent relative and maintain this condition
for eight hours.
14

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business