| ![]() MIL-R-83726/13G
TABLE I. Available time delay relays. 1/
Dash number
Time delay in seconds
Dash number
Time delay in seconds
10%
10%
16
-1602
.05
-0500
18
-1802
.10
-1000
20
-2002
.20
-2000
22
-2202
.30
-3000
25
-2502
.50
-5000
30
-3002
.75
-7500
35
-3502
1.0
-1001
40
-4002
2.0
-2001
45
-4502
3.0
-3001
50
-5002
4.0
-4001
55
-5502
5.0
-5001
60
-6002
6.0
-6001
100
-1003
7.0
-7001
200
-2003
8.0
-8001
300
-3003
9.0
-9001
400
-4003
10
-1002
500
-5003
12
-1202
600
-6003
14
-1402
1/
Additional time delay relays within the 0.05 to 600 second delay range are
available. To establish Part or Identifying Numbers (PIN's) not listed in table I
(see "PIN" herein).
Input data:
Input voltage: 28 Vdc nominal; range 18 Vdc to 31 Vdc.
Duty rating: Continuous.
Current drain: 10 milliamperes maximum, plus load current.
Reverse polarity protection: The timer will not be damaged or operate when input voltage polarity
is reversed.
Output data:
Configuration: SPSTNO, solid state switch closure to ground.