Load ratings:
Resistive: 300 milliamperes at 25C, derated to 100 milliamperes at +125C. Minimum load
current of 10 milliamperes is required.
Inductive: Three MIL-PRF-39016/6 relays or equivalent with 26.5 Vdc coil voltage.
Lamp load: Two M6363/8-5 lamps in accordance with MIL-DTL-6363 or equivalent.
Motor load, dc: Not applicable.
Inductive load, ac: Three MIL-PRF-39016/6 relays or equivalent.
Resistive load, ac: Not applicable.
Motor load, ac: Not applicable.
Load suppression: Suppression for inductive loads for output protection is provided within the unit.
Voltage drop: 2.5 volts maximum at -55C and +25C, 2.0 volts maximum at +125C.
Leakage current: 1 microampere maximum at 25C, 10 microamperes maximum at +125C.
Continuous current: Not applicable.
Overload: Not applicable.
Electrical data:
Insulation resistance: 1,000 megohms minimum at 500 V dc. 1/
Dielectric withstanding voltage: 500 V rms, 60 Hz, (sea level). 1/
Transients:
Voltage surge: In accordance with MIL-STD-704, figure 9, limit 1, for category B equipment.
Self-generated spikes: 10V.
Spike susceptibility: Not applicable.
Radio interference: Not applicable.
1/ Measured between all terminals tied together to the case.