Environmental data:
Temperature range: -55C to +125C.
Altitude: 80,000 feet.
Shock: 150 g's for 11 1 ms half-sine wave.
Vibration (sinusoidal): 10 Hz to 80 Hz at 0.06 inch DA. 80 Hz to 3,000 Hz at 20 g's.
Vibration scan: Not applicable.
Acceleration: Not applicable.
Seal: Method 112 of MIL-STD-202, condition C.
Solderability: Not applicable.
Physical data:
Dimensions and configuration: See figure 1.
Terminal strength: Bend test not applicable.
Weight: 12 grams maximum.
Verification:
Qualification: Group B and C are not applicable.
Conformance: Group A to MIL-R-83726 only.
Marking: See MIL-R-83726. In addition, relays shall be marked with the ESDS identifier
as specified in MIL-STD-1285.
ESDS protection program: The manufacturer shall establish and maintain an ESD control program.
Relays shall be handled, preserved, and packaged in such a manner as to ensure that the integrity of
ESD sensitive relays is not diminished. ESD sensitive relays shall be handled, preserved, and packaged
in accordance with the requirements of MIL-STD-1686.