MIL-R-83726/27K
REQUIREMENTS:
Operating data:
Configuration: SPDT.
Life/load ratings: See table I.
Timing action: See table II.
TABLE I. Life/load ratings (relay case grounded).
Amperes
Type of load
Life (cycles)
28 V dc
Resistive
100,000
2.0
Inductive
50,000
0.5
Lamp
100,000
0.2
Mechanical life
400,000
0.5
(reduced current)
Intermediate
100,000
0.50
current
Contact drop:
Initial: 0.150 volt maximum.
After life tests: 0.175 volt maximum.
Minimum current: 0.050 ampere.
Contact bounce: See table II.
Overload:
DC: 8 amperes minimum.
AC: Not applicable.
Rupture:
DC: 10 amperes minimum.
AC: Not applicable.
Input data:
Duty ratings: Continuous.
Input voltage:
Maximum: See table II.
Rated: See table II.
3