| MIL-R-85320(AS)
CAUTION
The ejector unit shall not be fired without a reactive
store load imposed on the ejector foot.
a.
The hooks of the ejector unit shall be closed and it
shall be verified that the hooks latch.
b.
Rotate the safety stop lever to "locked". Attempt
to release the ejector unit using the manual release
lever.
The maximum force applied shall be
Newtons (45 pounds).
The release mechanism shall
not actuate.
c.
Rotate the safety stop lever to "unlocked". Release
the ejector unit using the manual release lever.
Release force shall be between 67 and 200 Newtons
(15 and 45 pounds).
The release mechanism shall
operate smoothly and the hooks shall open.
d.
The hooks of the ejector unit shall be latched and a
total down load of 22,240 Newtons (5,000 pounds)
(11,120 Newtons, 2,500 pounds per hook) applied to
the ejector unit. There shall be no damage to the
ejector unit. Rotate the safety stop lever to the
"locked" then "unlocked" position. There shall be
no interference or binding.
e.
The load on the ejector unit shall be reduced to
3,558 Newtons (800 pounds) 1,779 Newtons, (400
pounds per hook). Release the ejector unit using the
manual release lever. The release force shall be
between 67 and 200 Newtons (15 and 45 pounds). The
release mechanism shall operate smoothly and the
hooks shall open.
Suspend a 113 kilogram (250 pound) store from the
f.
ejector unit, rotate the safety stop lever to "lock-
ed", and adjust the swaybraces as follows:
Hand tighten all braces until the pads lightly
1.
contact the store.
2.
Tighten the
forward starboard pad 1/4 turn.
3.
Tighten the aft port pad 1/4 turn.