MIL-R-8592/1
4. 4
Quality conformance inspection - The quality conformance
inspection shall consist of the tests listed in Table I.
4.4.1
Inspection lot -
Cable grips - An Inspection lot shall consist of all the
4.4.1.1
cable grips manufactured from essentially the same components under
essentially the same conditions offered for acceptance and delivery at
one time.
4.4.1.2
Preparation for delivery - An inspection lot size shall
be expressed in units of one fully prepared shipping container fully
prepared for delivery with the exception It need not be sealed.
4.42
Sampling for tests and examination of the cable grip -
The sample size, acceptance criteria, examinations and tests required
for the cable grip shall be as specified in Table I.
TABLE I
Sample Size, Acceptance Criteria, Examinations and Tests
Paragraph
Type of
Sample
,
Acceptance Criteria
Inspection
Rqmnt  Method
Size
Visual
Critical.
4.5.1
Reject all units with
Every grip
Examination
and
for critical
any critical defects
Minor
defects and
and an acceptable
Inspection
quality level of 6.5
Level II 1/
defects per hundred
for minor
units for minor defects
defects
3.4.1
Proof load
Critical
4.5.3
2 from each
Reject  all  defective
1000 or
units.  Acceptance
fraction
number zero rejection
thereof
number one
Preparation
Major
4.5.2
Inspection
Total AQL of 4.0 per-
for delivery
Level S-2 1/
cent defective
1/ The sample size shall be based on the applicable size code letter cor-
responding to the specified inspection level of MIL-STD-105.
4.5
Ins pection method -
4.5.1
Visual examination - Every cable grip shall be visually
examined for defects to determine conformance to the requirements of this
specification and Military Standard Drawing No. 90382. The classificatio.
and list of defects, Table II, shall be used to classify and enumerate the
defects found.
4