MIL-S-17000/12(SH)
-
2 May 1983
MILITARY SPECIFICATION SHEET
SWITCHING EQUIPMENT, COMBAT SYSTEM, COMMAND AND CONTROL,
FIRE CONTROL AND INTERIOR COMMUNICATION SWITCHBOARD, SUBMARINE
DECK-MOUNTED (PLUG CONNECTED)
TYPE XII
This specification sheet is approved for use-by the Naval `Sea Systems
Command, Department of the Navy, and is available for use by all
Departments and Agencies of the Department of Defense.
The complete requirements for acquiring the switchboard described herein
shall consist of this document and the latest issue of MIL-S-170000
REQUIREMENTS:
Switchboard shall be in accordance with Drawing 417-5476783.
Switchboard:
Mounting:  Switchboard enclosure shall be provided with mounting bolt
clearance holes as shown on Drawing 417-5476783 (sheet 3). Mounting foot at
the bottom, to be an integral part of the enclosure.
Panel-mounted assemblies:
Switchboard shall use standard panel-mounted
assemblies as specified in MIL-STD-1657.
Arrangement:  Arrangement and types of switches, fuses, and lights shall
be as specified in the acquisition technical data package.
Switchboard section arrangement:  Switchboard section shall be arranged
as shown on Drawing 417-5476783 (sheet 2). The front section shall
provide space for 36 panel-mounted assemblies mounted on a door, hinged on
one side and latched on the other.  The back section shall contain six modules.
Space for 12 panel-mounted assemblies shall be provided to the left of the
door hinge.
Size: Size of the switchboard section shall be as shown on Drawing
417-5476783 (sheet 2) (be capable of passage through a 30-inch aisle passage-
way with a minimum of 6 feet, 6 inches head room).
Terminals:  Subject to space limitations, spare' terminals up to 20 percent
of active terminals shall be provided on terminal boards for ship wires, The
21 terminal boards (type 7TB12) shall be in accordance with MIL-T-55164/13 as
specified in the acquisition technical data package.