Click here to make tpub.com your Home Page

Page Title: Rated Torque Calibration
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
APPLICABLE
PARAGRAPH OF
SPECIFICATION
Note:
The above values do not allow for flywheel windage
losses, test stand drag, or inertia of the starter.
In order to determine compliance with this specifi-
cation, the test results corrected accordingly. If
the acceleration specified for Phase C is not de-
veloped because of test stand drag torque, the test
stand inertia load may be reduced or external power
may be applied to assist acceleration to cutout speed.
Time from end of Phase C to starter cutout shall not
exceed 15 seconds.
Rated Torque Calibration:
4.5.8
Minimum Output Drive Speed (RPM): 1100
Airflow, Max (Lb per Min): 90
Overrunning: The starter output drive shall be driven
3.3.5
for 1000 hours in a clockwise direction (viewed
4.5.9
from the anti-output shaft end) in accordance with
the following tabulation:
Starter Drive overrunning Speed RPM 200
Phase C
Phase B
Phase A
200 Hrs
50 Hrs
--
7000
4360
6800
Extreme Temperature Operation:
4.5.10
Inlet Air Conditions
Total
Ambient
Total Press.
Temp (F)
Temp (F)
In. Hg A 0.5
-65
260
140
90
+160
445
Consecutive Cyclical Op eration:
No. of cycles: 5
4.5.11

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business