The variable voltage control shall be
4.6.9.2 Procedure.
set to deliver 60 volts to the heating rod. At the end of 5
minutes (using the electric timer), the setting of the variable
voltage control shall be increased to 0 100 volts. When the
temperature of the barrel reaches 700 F, the setting of the
variable voltage control shall be increase to 120 volts and
maintained at 0 that setting until the temperature of the barrel
reaches 1,200 F, the current shall be discontinued and the rifle
allowed to cool. After cooling, the stock assembly without butt
plate shall be examined to determine if the requirements have been
met.
4.6.10 Packaging tests.
4.6.10.1 Determination of cleanliness. The surfaces of
each sample unit shall be subjected to the determination of
cleanliness test specified in MIL-P-116.
4.6.10.2 Heat-sealed seam and quick leak. The heat-sealed
bags in the level A sample unit packages shall be subjected to
the heat-sealed seam test and the quick leak test specified in
The static load for the heat-sealed seam test shall be
MIL-P-116.
36 ounces.
5.
PACKAGING
5.1 Pilot pack. A pilot pack consisting of a complete and
packed unit and intermediate packages, as applicable, packaged in
accordance with Packaging Data Sheet P5910348 to the level of
protection specified in the contract (see 6.1) and packed level C
shall be forwarded as specified in 3.1.
5.2 Preservation, packaging, packing and marking. Stock
assemblies shall be preserved, unit packaged, packed and marked in
accordance with the requirements of Packaging Data Sheet P5910348
for the applicable level of protection specified (see 6.1).
NOTES
6.
(This section contains information of a general or
explanatory nature that may be helpful, but is not mandatory.)
The stock is intended for use with the
6.1 Intended use.
Rifle, 7.62mm: M14.