| MIL-S-52124B(ME)
Material not as specified.
Parts or components missing or do not function.
Assembly incomplete or incorrect.
Safety devices or guards missing.
Workmanship not as specified.
Ease of maintenance not as specified.
Dimensions or weight not as specified.
Treatment and painting not as specified.
Identification or other marking, operating, and safety
instructions, or manuals missing.
Lubrication devices not accessible.
Foundation brake protection not as specified.
Brake system not as specified or does not function.
Electrical system not as specified, does not function,
or is damaged.
Oil or grease seals leaking.
Bearings or gear boxes overheating.
Shaft misalinement.
Belt does not run straight on the centerline of the
conveyor.
Nonconformance to ICC regulations.
Center-of-gravity height not as specified in 3.1.2(m). t
no
Electromagnetic interference suppression components
identical with approved model.
4.6.2 Tests. Prior to test, lubricate the screening unit those desig-
with
Oils shall be
military oils and greases specified in 3.18.
nated for use in the ambient temperature at which the test is being
performed.
4.6.2.1 Screening.
4.6.2.l.1 Test conditions.
(a) Operating time. The production capacity of the screening unit
shall be computed on the basis of the net operating time
which is defined as gross operating time less allowable
down time for the following:
(1) Delay due to lack of material delivery to the
screening unit.
(2) Normal machinery maintenance. (Down time due to
any design deficiency shall not be considered normal
maintenance. )
|