Click here to make tpub.com your Home Page

Page Title: Composition, black smoke
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-S-70536(AR)
4.5.2.2 Composition, black smoke.  The method of determining
the percentage of moisture in the black smoke composition shall be
in accordance with method 101.2.1 of MIL-STD-1234.  Observation
shall be made for compliance with the applicable requirement.
4.5.3 Functioning.
(Ambient temperature, 21 3C, 70
5F, Hot, 51.5 3C, 125 5F, Cold, -32 3C, -25
5F).  The simulator assemblies shall be conditioned for 6 hours
min. at the specified temperatures and fired within 5 minutes after
removal from the conditioning chamber.  The simulator shall be held
in a rigid support and fired by means of an approved power source in
(Destructive test)
accordance with 3.3.2.
4.5.3.1 Visual signature.  Measurement shall be made from a
side position to the longitudinal axis of the simulator with an
approved method in accordance with para. 4.4.4.  Observation shall
be made for compliance with the applicable requirement.
4.5.3.2 Functioning time.  The time from initiation of the VDC
shall be measured with approved metering equipment in accordance
with para. 4.4.4.  The assembly shall be observed for compliance
with the requirements of 3.3.2.
4.5.3.3 Resistance test.
(Dwg. 9354515)  The match and cable
assembly shall be tested for the specified resistance with
inspection equipment approved in accordance with para. 4.4.4.
Observation shall be made for compliance with applicable
requirements.
(Non-Destructive Test)
4.5.4 Environmental tests.  Environmental testing shall be
conducted to determine compliance with the requirements of 3.4.
4.5.4.1 Low temperature.  This test shall be conducted in
accordance with Method 502.2, Procedure I of MIL-STD-810, except
that the simulator shall be exposed to a temperature of -25 5F
until thermal stabilization is reached and maintained for a period
of 6 hours (min.); then the simulator shall be test fired.  When
necessary, the test specimens may be removed from the conditioning
cabinet, set up, and fired within a period of time not to exceed 5
minutes.  Observation shall be made for compliance with the
applicable requirement.
4.5.4.2 High and ambient temperature.  This test shall be
conducted in accordance with Method 501.2, Procedure I of
MIL-STD-810 except that the simulator shall be exposed to a
temperature of 125 5 and ambient temperature of 70 5F
until thermal stabilization is reached, and maintained at that
21

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business