| MIL-T-46692B
205 Cut, damaged, or improperly sealed bag
Visual
4.2.2.5 Box, Ammunition, Packing, Drawing 8845243.
Critical
None defined
Major
None defined
Minor
201 Contents loose Manual
202 Strapping missing, loose, broken, or improperly engaged
Visual/Manual
203 Contents of box exposed Visual
204 Box damaged Visual
205 Marking missing, incorrect, or illegible
Visual
206 Number of units incorrect Visual
4.2.2.6 Box, Fiberboard (Outer), Alternative, Ammunition, Packing, Drawing 9217557.
Critical
None defined
Major
None defined
Minor
201 Contents loose Manual/Visual
202 Carton broken or damageVisual
d
203 Number of units contained incorrect
Visual
204 Marking missing, incorrect, or illegible
Visual
205 Tape incomplete
Visual
4.2.3 Inspection testing. The following tests shall be performed in accordance with 4.3.
4.2.3.1 Breakaway torque.
4.2.3.1.1 Head and cylinder. Each head and cylinder shall be subjected to a breakaway torque.
Failure of any subassembly to comply with the requirements of column B, table I in 3.3 shall be
cause for rejection of the subassembly.
4.2.3.2 Residual magnetism. Each assembly shall be subjected to the test for excessive
residual magnetism as specified in 4.3.2. Failure of any unit to comply with 3.4 shall be cause
for rejection of the assembly.
4.2.3.3 Functional tests. The following tests shall be performed by the Government.