Click here to make tpub.com your Home Page

Page Title: Methods of inspection
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-T-48558B(AR)
TABLE
III
ROOM
OPERATING
STORAGE
TEMP
SOAK
SOAK
TEMP
TEMP
SOAK
SEQ
+160F(71C)
4 hrs.
1
2 hrs.
+150F(65C)
2
+60F to 90F 3 hrs.
3
(+16C to +32C)
4 hrs. -50F(-46C)
-50F(-46C)
4 hrs.*
4
+60F to 90F 3 hrs.
5
(+16C to +32C)
*
Same
4
hrs
as
Storage
Soak
4.7.2  S h o c k .  This  test  is  applicable  to  the  First  Article
The  telescope
samples and the reliability assurance sample only. The telescope
shall  be  positioned  on  Adapter  10549199  and  secured  to  the  shock
tester.  The  telescope  shall  then  be  subjected  to  a  shock  test  in
accordance  with  3.6.3  Upon  completion  of  the  shock  test,  the
telescope  shall  be  subjected  to  a  visual  and  tactile  examination
and  shall  meet  the  requirements  of  3.7.3.
4.7.3 Vibration "A". This test is applicable to the First
4.7.3  Vibration  "A".
The
Article samples and the reliability assurance sample only. The
telescope  shall  be  positioned  on  Adapter  10549199  and  secured  to
the  vibration  test  in  accordance  with  3.7.4  of  this  specification.
Upon  completion  of  the  vibration  test,  the  telescope  shall  be
subjected  to  a  visual  and  tactile  examination  and  shall  meet  the
requirements  of  3.7.4.
4.7.4  Vibration  "B".  The  frequency  and  duration  shall  be  as
outlined  in  3.7.4.2.  At  the  conclusion  of  the  test,  the  telescope
shall  be  subjected  to  a  visual  and  tactile  examination  and  shall
meet  the  requirements  of  3.7.4.2.
4.8 Methods
of
inspection.
4.8.1  Orientation.  Test  Fixture  F10558254  shall  be  used  for
the  inspection  of  Elbow  Telescope  M138.  Position  the  test  fixture
on  a  vibration  free  surface  in  accordance  with  the  setup
instructions  outlined  on  drawing  F10558254.  Follow  the
calibration  and  setup  instructions  prior  to  positioning  telescope
to  the  fixture.  Subsequent  to  completion  of  all  setup
instructions,  the  telescope  shall  be  orientated  as  specified  in
paragraph  3.6  of  this  specification.
4.8.2  Collimation.  The  telescope  shall  be  positioned  as
specified  in  paragraph  3.6.  The  intersectinq  point  of  the
boresight  cross  of  the  telescope  reticle  shall  be  within  the
tolerance  block  of  the  target  reticle.  The  intersecting  point
must  be  within  the  limit  specified  for  the  collimation  of  reticle,
13