MIL-T-48621A (AR)
3.3.10 Temperature.
3.3.10.1 Temperature. (non-operating).
The Noise Tester shall
be capable of withstanding the temperature test requirements as
defined in MIL-STD-81O, Method 501, Procedure 1, without being
damaged or adversely affected.  The Noise Tester shall be
temperature stabilized at +70 + 2 degrees C and -62 + degrees C for
a period of 24 hours at each temperature extreme.  After each of the
above temperature tests, the Noise Tester shall be temperature
stabilized at 25 + 5 degrees C for at least two hours.  Subsequent
to the temperature stab ilization period, the Noise Tester shall not
have been damaged or adversely affected and shall meet all
requirements of 3.3.2 (see charts below).
I
..
Finish
NON-OPERATING HIGH TEMPERATURE TEST SEQUENCE
Finish
To + 24 hrs.
NON-OPERATING LOW TEMPERATURE TEST SEQUENCE
o
TEST
=
Test to para 3.3.2.
9