| MIL-T-48621A (AR)
3.3.10.2 Temperature (operating).
3.3.10.2.1 High temperature. The Noise Tester shall be capable
of withstanding the temperature test requirements as defined in
MIL-STD-81O, Method 501, Procedure I, without being damaged or
adversely affected. The Noise Tester, after a minimum of three
- hours temperature stabilization at +55 + 2 degrees C with nominal
primary power applied (+24 + 1VDC), shall be capable of continuous
I
operation for four hours. During the four-hour operating Interval,
the Noise Tester shall be tested in the first and third hours to
meet all requirements of 3.3.2 (see chart below).
To
55
.
o
Finish
TEST
=
TEST TO PARA. 3.3.2
Start
HIGH OPERATING TEMPERATURE TEST SEQUENCE